Hose | 1/2" ID x 6' |
Requirements shown are per spray bar
Requirements
Chemical Concentrate |
---|
Water | |
---|---|
Temperature | up to 160°F |
Pressure | 35 to 125 PSI |
Flow | 4.0 GPM @ 40 PSI |
Supply Line | 3/4" |
Nozzle | 100 Spreader |
Hose | 1/2" ID x 6' |
Requirements shown are per spray bar
Overview
Safety & Operational Precautions
To Install (refer to diagram on next page)
Set the chemical dilution ratio by threading one of the color coded metering tips into each chemical check valve. See chemical labels for dilution ratio recommendation or consult your chemical supplier.
To Operate
NOTE: 2-arm units have 2 injector bodies/arms/nozzles with independent activation ball valves. Installation and operation for 1 and 2-arm models is fundamentally the same.
Metering Tip Selection | ||
---|---|---|
Metering Tip Color |
OZ/MIN |
Dilution Ratio |
Brown | 0.56 | 914:1 |
Clear | 0.88 | 582:1 |
Bright Purple | 1.38 | 371:1 |
White | 2.15 | 238:1 |
Pink | 2.93 | 175:1 |
Corn Yellow | 3.84 | 133:1 |
Dark Green | 4.88 | 105:1 |
Orange | 5.77 | 89:1 |
Gray | 6.01 | 85:1 |
Light Green | 7.01 | 73:1 |
Med. Green | 8.06 | 64:1 |
Clear Pink | 9.43 | 54:1 |
Yellow Green | 11.50 | 45:1 |
Burgundy | 11.93 | 43:1 |
Pale Pink | 13.87 | 37:1 |
Light Blue | 15.14 | 34:1 |
Dark Purple | 17.88 | 29:1 |
Navy Blue | 25.36 | 20:1 |
Clear Aqua | 28.60 | 18:1 |
Black | 50.00 | 10:1 |
No Tip Ratio Up To: | 9:1 | |
The dilution ratios above are approximate values. Due to chemical viscosity, actual dilution ratios may vary. | ||
Formula | ||
GPM × 128 ÷ Desired Dilution Ratio = oz/min
|
Unit Flow Rates | |
---|---|
PSI | GPM |
35 | 3.74 |
40 | 4.00 |
50 | 4.47 |
60 | 4.90 |
70 | 5.29 |
80 | 5.66 |
90 | 6.00 |
100 | 6.32 |
110 | 6.63 |
120 | 6.93 |
125 | 7.07 |
Troubleshooting Guide |
---|
Problem | Possible Cause / Solution | |
---|---|---|
Startup | Maintenance | |
A) Unit will not draw chemical B) Dilution too weak C) Dilution too strong D) Water backing up into chemical container | 1, 4, 5, 6, 7 2, 4, 5 3 |
8, 9, 10, 11, 12, 13, 14 8, 9, 10, 11, 12, 13, 14 14 8 |
Possible Cause / Solution | |
---|---|
Startup | Maintenance |
|
|
PREVENTIVE MAINTENANCE: When the unit will be out of service for extended periods, place chemical tube(s) in water and flush the chemical out of the unit to help prevent chemical from drying out and causing build-up. Periodically check and clean chemical strainer and replace if missing. |