Lafferty Catalog 6 • Entryway, Drain & Hand Sanitizing Systems

ENTRYWAY SATELLITE CONTROLLERS REQUIRES: ELECTRICITY, COMPRESSED AIR SATELLITE ENTRYWAY FOAM SANITIZERS REQUIRES: 35-125 PSI WATER, CHEMICAL CONCENTRATE (& COMPRESSED AIR FROM CONTROLLER) Model # Description For Walk Doors (3 ft.) 976650 Satellite Entryway Foam Sanitizer For Double Doors (6 ft.) 976651 Satellite Entryway MV Foam Sanitizer Option: 976012 Entryway Dual Chemical Pick-up Assembly Model # Description 120 Volt models for use in the USA 976625 Timed Entryway Satellite Controller 976630 PLC Jazz Entryway Satellite Controller 24 Volt models for use outside the USA 976625-24V Timed Entryway Satellite Controller - 24VAC 976630-24V PLC Jazz Entryway Satellite Controller - 24VAC Timed Entryway Satellite Controller • Provides regular application cycles • Controls up to 10 satellite foamers — All foamers activate and deactivate at the same time • Adjustable timer controls the application (on/off) and delay (off) cycles • The same cycle settings repeat until the Controller is turned off. • Manual Override switch provides instant foam when needed • 24 Volt models, for use outside the USA, require a locally-sourced step-down transformer to provide 24 VAC power to the controller • For employee walk doors (3 ft. wide) and double doors (6 ft. wide) • Venturi foamer draws chemical concentrate and dilutes it to the required ratio • Optional dual chemical pick-up assembly for adding foaming agent Includes • NEMA rated control box • Machined polypropylene foamer body • Stainless steel mounting plate • Color-coded metering tips (20) • Metering tip driver • 10' discharge hose with Lafferty Spreader nozzle PLC Jazz Entryway Satellite Controller • Allows variable settings for holidays, weekly or seasonal changes in hours of operation and peak and off-peak traffic demands. • Controls up to 10 satellite foamers — All foamers operate in accordance with a single set of programmed commands • Manual override for on and off cycles, without affecting the programming • Features straightforward, menu-driven programming options • 24 Volt models, for use outside the USA, require a locally-sourced step-down transformer to provide 24 VAC power to the controller Spreader nozzle These controllers work with any combination of satellite units: • Satellite Foam (Walk Door) • Satellite MV Foam (Double Door) • Satellite HV Foam (Wide / Overhead Door). Satellite Foamers within 300 ft. of the controller require a minimum 1/2" air header from the controller to the satellite. Air @ 100 PSI. Satellite Foamers 300-400 ft. from the controller require a minimum 3/4" air header from the controller to the satellite. Air @ 100 PSI. Lafferty 6 •CAT.6 LAFFERTY ENTRYWAY SATELLITE SYSTEMS use one Entryway Satellite Controller to uniformly regulate up to 10 Satellite Entryway FoamSanitizers in applying a layer of rich foam sanitizer to entryway floors to prevent cross contamination from foot or wheeled traffic. These are water-driven venturi systems that accurately dilute chemical concentrates to required ratios. A container of chemical concentrate is required at each entryway. Satellite Foam Sanitizers are activated and operated by compressed air from the Satellite Controller — no electrical connection is required at the entryway location VENTURI SYSTEMS • Timed Controller • PLC JAZZ Controller Fax order • 800-699-3719

RkJQdWJsaXNoZXIy Njk3NTY=