Chemical Concentrate |
Water | |
Temperature | up to 160°F |
Pressure | 35 - 125 PSI |
Flow | 7.2 GPM @ 40 PSI |
Supply Line | 3/4" |
Compressed Air | up to 1.25 CFM |
Hose | 3/4" ID x 40' |
Nozzle | |
Rinse | 4-Hole Rinse Nozzle |
Foam / Sanitize | 40150 |
Requirements
Chemical Concentrate |
Water | |
Temperature | up to 160°F |
Pressure | 35 - 125 PSI |
Flow | 7.2 GPM @ 40 PSI |
Supply Line | 3/4" |
Compressed Air | up to 1.25 CFM |
Hose | 3/4" ID x 40' |
Nozzle | |
Rinse | 4-Hole Rinse Nozzle |
Foam / Sanitize | 40150 |
Overview
Safety & Operational Precautions
To Install (refer to diagram on next page)
Set the chemical dilution ratio by threading one of the color coded metering tips into each chemical check valve. See chemical labels for dilution ratio recommendation or consult your chemical supplier.
To Operate
TO FOAM
TO RINSE
TO SANITIZE
Metering Tip Selection | ||||
---|---|---|---|---|
Metering Tip Color |
OZ/MIN |
Dilution Ratio | ||
Sanitize | Rinse | Foam | ||
Brown | 0.56 | 1234:1 | — | 149:1 |
Clear | 0.88 | 785:1 | — | 95:1 |
Bright Purple | 1.38 | 501:1 | — | 60:1 |
White | 2.15 | 321:1 | — | 39:1 |
Pink | 2.93 | 236:1 | — | 28:1 |
Corn Yellow | 3.84 | 180:1 | — | 22:1 |
Dark Green | 4.88 | 142:1 | — | 17:1 |
Orange | 5.77 | 120:1 | — | 14:1 |
Gray | 6.01 | 115:1 | — | 14:1 |
Light Green | 7.01 | 99:1 | — | 12:1 |
Med. Green | 8.06 | 86:1 | — | 10:1 |
Clear Pink | 9.43 | 73:1 | — | 9:1 |
Yellow Green | 11.50 | 60:1 | — | 7:1 |
Burgundy | 11.93 | 58:1 | — | 7:1 |
Pale Pink | 13.87 | 50:1 | — | 6:1 |
Light Blue | 15.14 | 46:1 | — | 5:1 |
Dark Purple | 17.88 | 39:1 | — | — |
Navy Blue | 25.36 | 27:1 | — | — |
Clear Aqua | 28.60 | 24:1 | — | — |
Black | 50.00 | 14:1 | — | — |
No Tip Ratio Up To: | 11:1 | — | 5:1 | |
The dilution ratios above are approximate values. Due to chemical viscosity, actual dilution ratios may vary. | ||||
Formula | ||||
GPM × 128 ÷ Desired Dilution Ratio = oz/min
|
Unit Flow Rates | |||
---|---|---|---|
PSI | GPM | ||
Sanitize | Rinse | Foam | |
35 | 5.05 | 6.73 | 0.61 |
40 | 5.40 | 7.20 | 0.65 |
50 | 6.04 | 8.05 | 0.73 |
60 | 6.61 | 8.82 | 0.80 |
70 | 7.14 | 9.52 | 0.86 |
80 | 7.64 | 10.18 | 0.92 |
90 | 8.10 | 10.80 | 0.98 |
100 | 8.54 | 11.38 | 1.03 |
110 | 8.95 | 11.94 | 1.08 |
120 | 9.35 | 12.47 | 1.13 |
125 | 9.55 | 12.73 | 1.15 |
Troubleshooting Guide |
---|
Problem | Possible Cause / Solution | |
---|---|---|
Startup | Maintenance | |
A) Foam surges and/or hose "bucks". B) Foamer will not draw chemical. C) Foam too wet. D) Foam does not clean properly. E) Using too much chemical. F) Water / Chemical backing up into air line. G) Water backing up into chemical container. H) Air or chemical solution backing up into water line. | 1, 2, 3, 4, 6, 7, 8, 9, 10 1, 3, 4, 7, 8, 9, 10 2, 3, 4, 6, 7, 8, 9, 10 1, 4, 6, 11 5 |
12, 13, 14, 15, 16, 18, 19 12, 13, 14, 15, 16, 18, 19 13, 14, 15, 16, 18, 19 17 12 20 |
Problem | Possible Cause / Solution | |
---|---|---|
Startup | Maintenance | |
A) Sanitizer will not draw chemical. B) Dilution is too strong. C) Dilution is too weak. D) Water backing up into chemical container. | 3, 7, 8, 9, 10 5 4 |
12, 13, 14, 15, 18, 19 18 |
Possible Cause / Solution | |
---|---|
Startup | Maintenance |
|
|
PREVENTIVE MAINTENANCE: When the unit will be out of service for extended periods, place chemical tube(s) in water and flush the chemical out of the unit to help prevent chemical from drying out and causing build-up. Periodically check and clean chemical strainer and replace if missing. |