Ready-to-Use Chemical Solution | |
---|---|
Temperature | up to 160°F |
Pressure | 35 to 100 PSI |
Flow | 4 GPM @ 40 PSI |
Supply Line | 1/2" |
Compressed Air | up to 6 CFM |
Hose | |
---|---|
Sanitize | 1/2" ID x 50' |
Foam | 1" ID x 50' |
Nozzle | |
---|---|
Sanitize | 2520 |
Foam | 50400 |
Requirements
Ready-to-Use Chemical Solution | |
---|---|
Temperature | up to 160°F |
Pressure | 35 to 100 PSI |
Flow | 4 GPM @ 40 PSI |
Supply Line | 1/2" |
Compressed Air | up to 6 CFM |
Hose | |
---|---|
Sanitize | 1/2" ID x 50' |
Foam | 1" ID x 50' |
Nozzle | |
---|---|
Sanitize | 2520 |
Foam | 50400 |
Overview
Safety & Operational Precautions
To Install (refer to diagram on next page)
A check valve is required on the foamer solution inlet to prevent air from going back into the solution line. (See Options)
To Operate
Always make sure the discharge is closed or pointed in a safe direction before turning inlet valve on. Discharge can be shut off at any time during operation but should not be left off for long periods of time with the inlet valve on.
TO FOAM
TO SANITIZE
Unit Flow Rates | ||
---|---|---|
PSI | GPM | |
Sanitize | Foam | |
35 | 1.59 | 3.74 |
40 | 1.70 | 4.00 |
50 | 1.90 | 4.47 |
60 | 2.08 | 4.90 |
70 | 2.25 | 5.29 |
80 | 2.40 | 5.66 |
90 | 2.55 | 6.00 |
100 | 2.69 | 6.32 |
110 | 2.82 | 6.63 |
120 | 2.94 | 6.93 |
125 | 3.01 | 7.07 |
Troubleshooting Guide |
---|
Problem | Possible Cause / Solution | |
---|---|---|
Startup | Maintenance | |
A) Foam surges and/or hose "bucks" B) Foam too wet C) Foam does not clean properly D) Air backing up into foam solution line E) Chemical solution backing up into airline | 1, 2, 3, 4, 5, 7, 8 2, 3, 4, 7, 8 1, 4, 9 |
10, 11, 14 12, 14 14 13 |
Problem | Possible Cause / Solution | |
---|---|---|
Startup | Maintenance | |
A) Sanitizer has weak spray | 2, 3, 6, 7 |
10, 11 |
Possible Cause / Solution | |
---|---|
Startup | Maintenance |
|
|
PREVENTIVE MAINTENANCE: When the unit will be out of service for extended periods, run water through the system to flush the chemical and help prevent chemical build-up. |